Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/09/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/31/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PEX TOO CLOSE TO CAN LIGHTS 2 PLACES 2) ALIGN PLATE PONY WALL KIT 3) BANG PLATE KIT 4) NO H2O POTABLE 5) STRAP H2O SERV 6) PUT H2O IN TUBS 7) R.H. AB AT GARAGE TO HOUSE SHEAR 8) SW1 - 32" OC SW2 - 24" OC GARAGE SHEARWALL (DIAGRAM) |