Date Description Inspector Results Comments
05/24/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/19/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
05/18/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NAIL OFF ALL PERIMETER JOINTS ON ROOF
2) AT SOUTH SIDE OF GARAGE, AT LEDGER OSB DECK IS TO SHORT, TOE NAIL WITH 8D'S AND INSTALL FLAT A3.5 TRUSS JOIST TO LEDGER, FOR MECH CONNECTION
3) NAIL OFF ALL HORIZONTAL JOINTS AT EXT. SHEAR WALLS