Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HIP PIECE OF OSB NOT NAILED OFF ON PITCHED ROOF, NORTH ROOF PLAN 2) ALL CONSTRUCTION MATERIALS MUST BE REMOVED FROM FLAT ROOF FOR INSPECTION 3) FHA STRAP BOTTOM PLATES AT PLUMBING CUTS 4) STRAP WEST SIDE WINDOW HEADER 5) H2.5 SEVERAL HIP TRUSSES 6) A-35'S DO NOT SUPPLY POSITIVE ATTACHMENT FOR FRONT PORCH RAFTERS TO GIRDER 7) CHECK OUT OF PLUMBING STUDS AT FRONT 6" PLATE STEP BACK 8) PROVIDE ALTERNATE HOLDOWNS WHERE THEY MISSED KINGS OR ARE OVER SPAULLED |