Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM00441
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/27/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1. WEST SIDE GARAGE SECURE LARGE HEADER TO STUDS PER DETAIL, STRAPS ON INSIDE. 2. FROM INSIDE STRAP 2ND. FLR. TO HEADER 3. SAME IJI'S DRILLED TOO CLOSE TO BEARING END, SEE TJI MANUAL. 4. WILL CHECK INTERMEDIATE |
|
06/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UPPER ROOF PLANE, NORTHEAST CORNER NOT NAILED OFF 2) WALL OSB NOT NAILED AT GARAGE-2ND FLOOR-N.W. CORNER 3) STRAP WEST SIDE HEADERS 4) WALL OSB NOT NAILED OFF AT S.W. CORNER 5) FRONT PORCH GIRDER HAS NO ATTACHMENT TO COLUMNS 6) FHA STRAP BOTTOM PLATE AT PLUMBING CUT 7) INSTALL ALTERNATE HOLDOWNS WHERE MISSED KINGS |