Permit: T05CM00419

Parcel: 118036900

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM00419

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/11/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/24/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TO MANY PERSONAL ITEMS IN GARAGE-SOMEONE MUST BE PRESENT
02/25/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ANCHOR BOLTS REQUIRED WITHIN 12" OF EACH BOTTOM PLATE END OR SPLICE AND A MINIMUM OF 2 ANCHOR BOLTS REQUIRED IN EACH PLATE/BOARD
2) ONE TRUSS CUT/NOTCHED IN 12 PLACES, HAVE TRUSS MANUFACTURER PROVIDE AN APPROVED REPAIR
3) CROSS BRACE 3 TRUSSES EACH END
4) INSTALL EXTERIOR PANELING ON WALLS
5) NO CITY APPROVED PLANS ON SITE
6) ROOF SHEATHING NAILING IS PER CODE