Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/19/2006 | FRAMING | Approved | IVRS - Inspection :* | |
06/15/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PENDING ALL TRADES 2) PROVIDE ROOF TOP TEST DWV SYSTEM |
|
06/08/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CAULK PORCHES FRAME/FOAM INTERSECTIONS 2) NEED NAIL PROTECTION PLATES AT MASTER TUB PEX AND ABS, AT TOILET ABS, CLOSET COPPER PIPES, KITCHEN SINK ABS, HALL BATH ABS, LAUNDRY ABS AND DRYER DUCT 3) BLOCK DUCT BOOTS 3 SIDES 4) SHIM TRIMMER/HEADER CONNECTIONS WHERE NEEDED 5) FIREBLOCK CHASE BEHIND ENTRY 4 GANG BOX 6) FHA STRAP EAST LIVING ROOM TOP PLATE AT GAS PIPE FOR OVER BORE 7) NEED DWV TEST 8) NEED OUTLET ON SOUTH KITCHEN WALL 9) INSTALL HALL BATH VENT DUCT 10) MOVE PEX FROM LAUNDRY CAN LIGHT |