Permit: T05CM00376

Parcel: 115155150

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/11/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1) CONTRACTOR TO INSTALL FHA STRAPS AS REQUIRED
2) CLOSET FLANGES OK
3) TUBS OK
4) OK TO COVER ALL AREAS
07/06/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*1) NO MIDSTAY SUPPORT ON VERTICAL PIPING. 2) TUBS NOT HOOKED UP
07/05/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) WATER TEST ON ABS OK. RELEASE TEST, MAKE ALL CORRECTIONS, PROVIDE MID STORY SUPPORT ON VERTICAL VENT PIPING AND RECALL INSPECTION
3) PEX OK, TUBS INCOMPLETE AND CLOSET FLANGES OK
06/30/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :* 1) PROVIDE INSPECTION HISTORY FOR YARDWATER PIPING 2) NO TEST ON ABS. 3) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP. 4) NAIL GUARDS ARE NOT ACCEPTABLE SUBSTITUTE FOR FHA STRAPS. INSPECTION STOPPED.