Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) CONTRACTOR TO INSTALL FHA STRAPS AS REQUIRED 2) CLOSET FLANGES OK 3) TUBS OK 4) OK TO COVER ALL AREAS |
|
| 07/06/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*1) NO MIDSTAY SUPPORT ON VERTICAL PIPING. 2) TUBS NOT HOOKED UP |
|
| 07/05/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) WATER TEST ON ABS OK. RELEASE TEST, MAKE ALL CORRECTIONS, PROVIDE MID STORY SUPPORT ON VERTICAL VENT PIPING AND RECALL INSPECTION 3) PEX OK, TUBS INCOMPLETE AND CLOSET FLANGES OK |
|
| 06/30/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE INSPECTION HISTORY FOR YARDWATER PIPING 2) NO TEST ON ABS. 3) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP. 4) NAIL GUARDS ARE NOT ACCEPTABLE SUBSTITUTE FOR FHA STRAPS. INSPECTION STOPPED. |