Permit: T05CM00339

Parcel: 140383600

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/18/2005 FRAMING Approved IVRS - Inspection :*
05/17/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RED HEAD ANCHOR BOLTS LOOSE
2) SHEAR BLOCK MISSING AT GARAGE AND KITCHEN
3) HEADERS MUST BEAR ON TRIMMERS
4) NAIL PROTECT RANGE HOOD DUCT
5) STUCCO LATH INSTALLATION DOES NOT COMPLY WITH ICBO REPORT ER ? AND 1994 ? TABLE 25-B AT POP OUTS
6) SHEARWALL 6 NOT NAILED PER PLAN WEST PANEL AND 8' SEAM
7) DBL TOP PLATES MUST BEAR AT 16" ON CENTER
8) SHEAR NOT NAILED PER 5/DT1
9) FIRE BLOCK CHASE AT N.W. CORNER