Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/12/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/11/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) RED HEAD ANCHOR BOLTS LOOSE 2) NO DWV WATER TEST 3) GARAGE SHEARWALL HOLDOWN WRONG LOCATION 4) ALL WIRES MUST TERMINATE IN APPROVED ELECTRIC BOXES 5) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 6) TWO ANCHOR BOLTS REQUIRED EACH SILL PLATE AT LEAST 3 1/2" APART 7) PLUMBING OUTSIDE OF WALL CAVITY AT KITCHEN 8) GALVANIZED METAL CANNOT CONTACT COPPER AT KITCHEN 9) RC WB OUT OF WALL 10) NO GAS TEST 11) STOPPED INSPECTION, TO MANY ITEMS |
|
| 05/09/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH MUST BE FINISHED BEFORE INTERMEDIATES ARE INSPECTED |