Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/02/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 08/01/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO WATER TEST DWV SYSTEM |
|
| 07/29/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO DWV WATER TEST PER UPC 712.2. YOU MUST HAVE A 10 FT WATER COLUMN TEST AT TIME OF INSPECTION 2) VENT FITTINGS CANNOT BE USED BELOW 6" ABOVE FLOOD RIM OF FIXTURE. VENT 90 FITTING AT KITCHEN SINK CANNOT BE USED 3) TO DARK UNDER FLOOR TO SEE PLUMBING. PLEASE EXPOSE OR PROVIDE LIGHT 4) PROVIDA A CITY APPRIOVED FRAME PLAN FOR ALL WOOD STRUCTURE WORK IN THIS PROJECT. FLOOR FRAME MUST BE INSPECTED |