Permit: T05CM00325

Parcel: 140324830

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T05CM00325

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/26/2005 BUILDING - FINAL Approved IVRS - Inspection :*
07/22/2005 BUILDING - FINAL Denied 1) LABEL SMOKE DETECTOR CIRCUIT IN PANEL
2) WATER HEATER VENT REQUIRES 3 SCREWS AT CONNECTION
3) GFCI PROTECTED OUTLETS REQUIRED WITHIN 24" EITHER SIDE OF KITCHEN SINK AND RT OF RANGE
4) ALL BEDROOM OUTLETS MUST BE ARC FAULT PROTECTED
5) 110 VOLT A/C SMOKE DETECTORS IN BEDROOMS MUST BE ARC FAULT PROTECTED
6) NO ATTIC LIGHT
7) NO FURNACE SPARK SHIELD
8) CERTS