Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM00315
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/16/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
04/25/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* ABOVE ISSUES HAVE BEEN CORRECTED. BACKFLOW ASSEMBLY WAS RELOCATED AND IS REQUIRED TO BE RE-CERTIFIED. A BACKFLOW ASSEMBLY WAS ADDED FOR THE IRRIGATION, I NEED TO SEE THE UPSTREAM CONNECTIONS AND A CERTIFICATION. |
|
04/18/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SAND INTERCEPTOR NOT CONNECTED TO SEWER AS DRAIN. PROVIDE METHOD FOR REMOVAL OF WASTE. 2. RP LOCATED INSIDE GARAGE AREA NEXT TO RAMP. PROVIDE MEANS TO CONTAIN DISCHARGE OF RELIEF. EMERGENCY EYE WASH STATIONS ARE CONNECTED DIRECTLY TO SANITARY DRAIN. 3. PROVIDE METHOD OF MAINTAINING A TRAP SEAL FOR EMERGENCY EYE WASHES. 4. PROVIDE BACKFLOW CERTS. 5. EMERGENCY SHOWER IS LOCATED NEAR A DOOR WAY, A FLOOR DRAIN IS NOT NEAR BY PROVIDE A MEANS TO PREVENT SLIPPAGE OF PERSONS WALKING THROUGH DOOR WAY. |