Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/13/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL FIREPLACE FLUE AND FIRESTOP 2) FIREBLOCK FURNACE ROOM PLENIUM 3) INSULATE FLEX FAMILY ROOM REGISTER 4) FIREBLOCK FAMILY ROOM SOFFIT 5) SECURE 4 GANG BOX FAMILY ROOM 6) PROVIDE COPPER AND GAS BONDS 7) NAIL PROTECT MASTER SHOWER ABS 8) BLOCK REGISTERS 3 SIDES 9) NO WATER TEST DWV SYSTEM 10) OVERSPAN MASTER BATH EAST WALL 11) FIREBLOCK MISSING MASTER BATH DROPPED CEILING 12) BLOCK MASTER TUB WALLS 13) FIREBLOCK SHOWER DROP MASTER 14) NAIL EVERY HOLE A-35 REAR PORCH |
|
| 12/13/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) STUCCO MESH MUST BE IN PLACE BEFORE INTERMEDIATE INSPECTIONS ARE PERFORMED |