Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/22/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRONT FAMILY ROOM NORTH EAST CORNER BRACED WALL PANEL NOT PER PLAN 20" PANEL 2) FRONT FAMILY BRACED PANEL NORTH WEST CORNER MUST BE 11'-0" PANEL 3) ALL NAILS PERTRUDE TO FAR IN BRACED PANELS 4) ALL BRACED WALL PANELS MUST BE 4'-0" PANELS 5) LOOSE BRACED WALL PANEL AT MAIN SERVICE 6) MASTER BEDROOM SOUTH EAST CORNER BRACED PANELS NOT PER PLAN 7) PROVIDE RETROFIT HOLDOWNS OR BUILD PER PLAN |
|
| 11/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) LEDGER A35'S ONLY EXCEPT STORAGE 2) MISSING A35 CLIPS STORAGE ROOM 2 X 6 AND 2 X 4 WALLS PER DETAIL 6/5 AND 1/5 |
|
| 11/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REVISED DETAIL SHOWS A35 EVERY STUD AT LEDGERS 2) A35'S MISSING MASTER BEDROOM EAST WALL DBL STUD AND HALLWAY OFF MASTER BEDROOM EAST WALL |
|
| 11/01/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEATHING AND HOLDOWNS INCOMPLETE 2) PLAN CALLS FOR 4-16D NAILS LEDGER INTO EACH STUD 3) H2.5 NOT NAILED CORRECTLY INTO TOP OF LEDGER 4) STOPPED INSPECTION |
|
| 10/25/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H2.5 EVERY STUD PER DETAIL (1) A.35 |