Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T05CM00292
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/26/2005 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :* | |
| 08/10/2005 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* 1) REAR LIVABLE AREA OK 2) CARPORT AND PATIO NOT READY |
|
| 07/25/2005 | BUILDING PRE-SLAB | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTEND AND FORM 2'-8" STEM EXTENDING INTO CARPORT 2) INSTALL PAHD42'S 14 PLACES 3) WRAP PLUMBING WITH FOAM |
|
| 07/22/2005 | BUILDING PRE-SLAB | Denied | PLUMBING NOT WRAPPED |