Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/09/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) P-3 SHEAR NOT NAILED PER PLAN 2) STUD MISSING 2ND FLOOR WEST (2 EACH) 3) O.S.B. SHEAR ENDS MUST BE ON SAME STUD 4) NORTH WALL P-1 SHEAR NOT NAILED PER PLAN 5) GARAGE P-3 NOT NAILED PER PLAN 6) C5 20 STRAPS NOT NAILED 7) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 8) HEADERS NOT BEARING TOP PLATES 9) NO LADDER ACCESS TO ROOF 10) STOPPED INSPECTION |
|
| 05/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GABLE END TRUSSES NOT CLIPPED PER 1/SD3 2) P-1 SHEAR NOT NAILED TOP AND BOTTOM PLATES 3) P-3 SHEAR NOT NAILED PER PLAN 4) CS 20 STRAPS NOT NAILED 5) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 6) 1/SD2 AND 2/SD2 NOT COMPLIED WITH 7) P-2 SHEAR NOT NAILED PER PLAN 8) ROOF NOT NAILED PER PLAN 9) HEADERS NOT BEARING TOP PLATES 10) NO TRUSS DRAWINGS ON SITE 11) STOPPED INSPECTION |
|
| 05/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* |