Permit: T05CM00270

Parcel: 140376000


Addresses:

6930 S GOSHAWK DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/13/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/09/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) P-3 SHEAR NOT NAILED PER PLAN
2) STUD MISSING 2ND FLOOR WEST (2 EACH)
3) O.S.B. SHEAR ENDS MUST BE ON SAME STUD
4) NORTH WALL P-1 SHEAR NOT NAILED PER PLAN
5) GARAGE P-3 NOT NAILED PER PLAN
6) C5 20 STRAPS NOT NAILED
7) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE
8) HEADERS NOT BEARING TOP PLATES
9) NO LADDER ACCESS TO ROOF
10) STOPPED INSPECTION
05/05/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GABLE END TRUSSES NOT CLIPPED PER 1/SD3
2) P-1 SHEAR NOT NAILED TOP AND BOTTOM PLATES
3) P-3 SHEAR NOT NAILED PER PLAN
4) CS 20 STRAPS NOT NAILED
5) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE
6) 1/SD2 AND 2/SD2 NOT COMPLIED WITH
7) P-2 SHEAR NOT NAILED PER PLAN
8) ROOF NOT NAILED PER PLAN
9) HEADERS NOT BEARING TOP PLATES
10) NO TRUSS DRAWINGS ON SITE
11) STOPPED INSPECTION
05/02/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*