Permit: T05CM00259

Parcel: 129131150


Addresses:

814 E 31ST ST #01

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/13/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
BE SURE THAT YOU HAVE 12" OF COVER FOR PROTECTION OF YARD WATER LINE.
01/12/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE WATER TEST ON WASTE & VENT PIPING
1 1/4 SCH 40 PVC YARD WATER LINE
OK PROVIDED THAT SOME FILL DIRT IS PROVIDED TO ENSURE A MIN. OF 12" OF COVER
01/10/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) WATER TEST ON TUBS-OK
2) TRAP ARM FOR LAVATORY CANNOT BE LARGER THAN 1 1/2"
3) SEPERATE WATER LINES TO BACK UNIT PER PLAN
4) 1 1/4" MAIN LINE NEEDED WHERE SUPPLING BOTH UNITS
01/04/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLEASE PROVIDE UNLOCKED ACCESS TO JOB (A COMBINATION LOCK WOULD WORK)
1. EACH UNIT SHALL HAVE SEPARATE SHUT OFF VALVES FOR WATER SUPPLY PIPING
2. WATER PIPING NOT PER PLAN
3. PROVIDE A PRESSURE GAUGE ON WATER SYSTEMS
4. PROVIDE CORRECT LONG RADIUS DRAINAGE FITTINGS ON HORIZONTAL WASTE PIPING, HORIZONTAL CHANGE OF DIRECTION PER SEC 1002.3, 706.3
5. TRAP ARM SIZE CANNOT CHANGE AND MUST BE INSTALLED PER CHAPTER 10 UPC
6. WASTE & VENT PIPING REQUIRES A WATER TEST
7. (2 OF THE 3 TUBS HAVE LOST SOME WATER) CHECK FOR LEAKS ON OVERFLOW, REFILL TO FLOOD LEVEL