Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING ABOVE CEILING
Permit Number - T05CM00249
Inspection Description - BUILDING ABOVE CEILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/20/2005 | BUILDING ABOVE CEILING | Approved | IVRS - Inspection :* | |
06/08/2005 | BUILDING ABOVE CEILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* WHEN 1/2" TRIM IS USED AT PERIMETER FOR CEILING GRID HANGER WIRES ARE REQUIRED WITHIN 8" OF WALL ON ALL SUPPORTS. THIS IS PER THE MANUFACTURER'S ASSOCIATION RECOMMENDATIONS |