Permit: T05CM00235

Parcel: 116010840

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
07/12/2005 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
06/30/2005 EXCAVATION/LAYOUT REBAR & ZON Cancelled
06/28/2005 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REBAR TO BE A MINIMUM OF 3" FROM DIRT ALL AREAS
2) RACK VERTICAL REBAR IN PLACE
3) SOME GRADE STAKES ARE LESS THAN 12" MINIMUM CONCRETE DEPTH REQUIRED
06/23/2005 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GRADE PINS NOT SET AT MINIMUM 12" THICK CONCRETE
2) MAINTAIN MINIMUM 3" CLEARANCE REBAR TO DIRT
3) FTGS NOT 18" WIDE
4) PLAN SHOWS STAIRS ON EAST SIDE OF DECK, LAYOUT IS FOR STAIRS ON WEST SIDE OF DECK
5) CANNOT LOCATE ENGINEER DETAIL
6) STOPPED INSPECTION
7) ELECTRIC (REAR) NOT ON PLAN ?
8) REFEE DUE
06/21/2005 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) (FRONT PORCH) REAR INCOMPLETE
2) PLAN CALLS FOR 18" WIDE FTGS AND 12" DEEP
3) MUCK OUT FTG AFTER MAINTANCE 18" X 12" FTGS
4) MAINTAIN MINIMUM 3" CLEARANCE REBAR TO DIRT
06/17/2005 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FOOTINGS NOT TO PLAN/CODE
2) MAINTAIN MINIMUM CLEARANCE REBAR 3" TO DIRT
3) REMOVE P.V.C. H20 LINE FROM FTG
4) INCOMPLETE
5) STOPPED INSPECTION