Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 08/17/2005 | BUILDING - FINAL | Cancelled | CANCELLED PER JERRY OF K.B. HOMES #907-6025 | |
| 08/17/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/12/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) TRIM CLEANOUTS TO GARDE 2) GRADE SOIL 2 PERCENT FALL FROM HOUSE FOR 5 FT 3) DBL LUGGED NEUTRAL WIRES NOT ALLOWED 4) CIRCUIT WIRES DAMAGED BY OVER TORQUE. REPAIR WIRES AND TORQUE TO LABEL SPECS. SAVE ALL DAMAGED WIRE ENDS FOR INSPECTION 5) FILL OPEN KNOCKOUT IN ELECTRIC SERVICE PANEL 6) MAXIMUM ALLOWED FUSE/CB FOR AC 40 AMP-50 INSTALLED 7) SEAL HOLES IN EXTERIOR WALLS 8) STOPPED INSPECTION HOUSE MUST BE COMPLETE AND READY TO OCCUPY PRIOR TO FINAL INSPECTION |