Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/08/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO INSULATE AND DRYWALL 2) REPAIR IS PER ENGINEERING DOCUMENT DATED 6/5/05. REPAIR DOCUMENT MUST BE CITY APPROVED 3) OK TO CONTINUE |
|
| 06/07/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TRUSS IS A STUBED TRUSS AND REAPIR DOCUMENT SHOWS A CONVENTIONAL TRUSS. CORRECT DRAWING 2) WEST REPAIR IS MADE UP OF THREE PIECES OF O.S.B. DRAWING SHOWS ONLY ONE. ENDS AND EDGES OF REPAIR PIECES ARE NOT BLOCKED OR NAILED. HAVE ENGINEER SPECIFY EXACTLY HOW TRUSS IS TO BE REPAIRED 3) HAVE ENGINEERING APPROVED BY CITY OF TUCSON |
|
| 05/10/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM 7 FROM 5/5/5 NOT COMPLIED WITH 2) OK TO INSULATE AND PARTIAL DRYWALL 3) DO NOT COVER-2ND FLOOR TRIPPLE TRUSS 4) ALL ELECTRIC OK BUT TRIPPLE GIRDER TRUSS |
|
| 05/05/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 7/SD2 AT SHEAR WALL G-3 NOT COMPLIED WITH BLOCSK REQUIRED EACH SIDE OF RANGE DUCT CUTS AND SEE NAIL SCHEDULE 2) SEAL FLOOR PENETRATIONS AT TUB 3) STAIR LIGHT SWITCH IS BEHIND HANDRAIL 4) NAIL 2ND FLOOR SHEAR WALL BOTTOM PLATES AT 12" ON CENTER 5) ELECTRIC OUTLET REQUIRED WITHIN 6 FEET OF STAIR TOP AT PONY WALL 6) NAIL 2ND FLOOR SILL PLATES AT 16' ON CENTER 7) TRIPPLE GIRDER TRUSS HAS 7 EACH HOLES DRILLED. PROVIDE CITY OF TUCSON APPROVED TRUSS ENGINEERING APPROVED REPAIR 8) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE |
|
| 05/04/2005 | FRAMING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* 1) 2889B HOUSE 2082 PLAN AND TRUSS DRAWINGS 2) NO PLANS ON SITE, NO INSPECTION |