Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/20/2005 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 06/16/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ADD NAIL PROTECTION PLATE, FOR WIRE, ON STUD JUST SOUTH OF ENTRY DOOR 2) SHIM BEARING WALL TRIMMERS/HEADERS/JACKS 3) NEED NAIL PLATE AT TOP PLATE FOR KITCHEN SINK WATER LINES AND MAIN DIAPHRAM WATER LINES AND ALL BATH LINES 4) TIGHTEN ANCHOR BOLTS OR ADD RED HEADS WHERE AB'S CAN'T BE TIGHTENED OR WHERE NEEDED ON WEST WALL 5) GROUT ENTIRE DIRT AREA UNDER TUB 6) PLAN SHOWS ALL V.T.R.'S-NOT AIR ADMITTANCE VALVES. ALSO A.A. VALVES CAN ONLY BE USED AFTER THERE IS A V.T.R. WITH A DIAMETER EQUAL TO THE MAIN DRAIN SIZE. FOLLOW PLAN OR HAVE PLAN CHANGED 7) FHA STRAP BOTTOM PLATES AT ABS PIPES 8) NEED TRUSS CROSS BRACING 9) NEED D.W.V. TEST |