Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/24/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) NORTH FURNACE VENT NOT PROPERLY INSTALLED |
|
| 06/23/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL GARAGE OUTLETS MUST BE GFCI PROTECTED 2) WATER HEATER GAS VALVE PRECLUDES UNIT REMOVAL WITHOUT REMOVING GAS S.O.V. 3) SOUTH AIR HANDLER DUCT INSULATION 6" FROM DUCT COLLAR 4) NORTH AIR HANDLER FURNACE SINGLE WALL TO DBL WALL CONNECTION NOT PROPERLY MADE. NOT SECURE AND SINGLE WALL BENT 5) M/BATH OUTLETS MUST BE GFCI PROTECTED 6) RANGE HOOD GROUND LOOSE |
|
| 06/21/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER RON |