Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T05CM00151
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/08/2005 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* ALL CORRECTIONS HAVE BEEN MADE | |
02/03/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* REPLACE T & P ON WATER HEATER. PROVIDE A DRAIN PIPE ON T& P VALVE. PROVIDE MIN 3 SCREWS IN VENT CONNECTOR ON WATER HEATER. GAS FLEX CANNOT PENETRATE THE CABINET OF WATER HEATER. PROVIDE ACCESS TO FURNACE. EXTEND FURNACE VENT 2' ABOVE EVAP COOLER. |