Permit: T05CM00151

Parcel: 122121290


Addresses:

1312 N VENICE AV


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T05CM00151

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/08/2005 MECHANICAL - FINAL Approved IVRS - Inspection :* ALL CORRECTIONS HAVE BEEN MADE
02/03/2005 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* REPLACE T & P ON WATER HEATER. PROVIDE A DRAIN PIPE ON T& P VALVE. PROVIDE MIN 3 SCREWS IN VENT CONNECTOR ON WATER HEATER. GAS FLEX CANNOT PENETRATE THE CABINET OF WATER HEATER. PROVIDE ACCESS TO FURNACE. EXTEND FURNACE VENT 2' ABOVE EVAP COOLER.