Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) METAL ROOF ADDITION EXISTING ON WEST SIDE NOT ON PLAN OR PERMITTED 2) PLANS SHOWS MASONRY WALLS-NEW WALLS ARE FRAME 3) NEED DRAIN WASTE AND VENT H20 TEST THROUGH ROOF 4) INSTALL METAL BANG PLATE NAIL PROTECTION ALL PLUMBING AND ELECTRIC THRU FRAMING 5) BLOCK 3 SIDES MECH DUCTS AT CEILING AREA 6) INSTALL H2.5 CLIPS TRUSSES AT ALL BEARING POINTS 7) FINISH FURR OUT OVER NORTH WINDOW AND PUT ROMEX INTO WALL 8) H20 LINES NOT RUN TO BATHROOM 9) RAMSET INTERIOR BEARING PLATE TO CONCRETE AND INSTALL H2.5'S BOTTOM PLATE TO STUDS: STUD TO BEAM; BEAM TO TRUSS 10) STOPPED INSPECTION 11) NEED VERIFICATION ON 1005, 1015 AND 1020 APPROVALS 12) NOT COMPLETE ENOUGH TO INSPECT |