Permit: T05CM00126

Parcel: 140376270


Addresses:

6971 S GOSHAWK DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/17/2005 FRAMING Approved IVRS - Inspection :*
06/15/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
06/08/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) STUCCO LATH NOT NAILED AT BOTTOM PLATES AT 6" ON CENTER
2) GARAGE P-3 SHEAR WALL REQUIRES HILTI PINS AT 3" ON CENTER
3) 2A HOLDOWN WRONG LOCATION MUST BE 13'-11" FROM OUTSIDE WALL ON DBL STUDS
4) CHANEL AT GARAGE NOT NAILED PER 10/SD4
5) WEST SHEARWALL REQUIRES ANCHOR BOLTS AT 16" ON CENTER
6) PLUMBING LEAK AT TUB
7) DUCT WORK RESTRICTED BY PLUMBING-GREAT ROOM
8) STOPPED INSPECTION-TO MANY ITEMS