Permit: T05CM00123

Parcel: 136312620

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/21/2005 FRAMING Approved IVRS - Inspection :*
1) OK TO INSULATE
2) COMPLETE MESH AT GABLE ENDS
3) COMPLETE CAULKING
04/19/2005 FRAMING Partial Approval IVRS - Inspection :*
1) FACE NAILED HANGER AHUS REQUIRES 16D NAILS NOT 10D
2) A/C LINE SET AT TOP PLATE, PAD AT FHA STRAP ADD STUD AT NOTCH
3) TUB BACKING VERT. HALL BATH, BOTH SIDES AND BOTH BATHROOM
4) 3 PT INTER BEARING SHIM
5) BANG PLATE EAST WALL ROMEX
6) J-HOOK REFER LINE
7) OVER SPAN STUD AT FRONT ENTRY
8) MISSING HORIZONTAL NAILING INTER SHEAR
9) OVERSPAN STUD LAUNDRY
10) SEE ALL MARKS ON FLOOR
11) GAS/DWV/POT H20-OK
12) FINISH STUCCO