Permit: T05CM00120

Parcel: 14117007Q


Addresses:

7545 S HOUGHTON RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T05CM00120

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
04/25/2007 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
10/20/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/12/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT OF TRASH ENCLOSURES (4)
09/01/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
2 NORTH TRASH ENCLOSURE -- 1ST LIFT OK TO GROUT
08/29/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT TWO SOUTH ENCLOSURES
08/23/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINTEL SPLICES @ TOP OF COLUMNS
H.25 CLIPS AT FACIA FRONT & BACK
07/27/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
07/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT OF NORTH PIER -- OK TO GROUT
06/30/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH END PIER TOP OUT & NORTH END PIER 4TH LIFT
OK TO GROUT.
06/28/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
OK TO GROUT
SOUTH COLUMNS
2-TOP OUT-1 4TH LIFT
NORTH COLUMN - 3RD LIFT
06/26/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 3 SOUTH COLUMNS 4TH LIFT-OK TO GROUT
2) 2 NORTH COLUMNS TOP OUT-OK TO GROUT
06/23/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LIP CAPS OK
06/21/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
FINAL LIFT ON WEST SIDE 13 COLUMNS @ COLUMN LINE 3 & SOUTH COLUMNS K @ 2.8
3RD LIFT ON NORTH COLUMN B @ 2.8
06/14/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MASONRY PROGRESS OK
06/13/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
RECALL WHEN BALANCE OF EAST COLUMNS READY -- BEFORE YOU GROUT (8 TO HEIGHT).
06/08/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MASONRY PROGRESS OK
06/07/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT - SOUTH 1/2 E WALL
06/02/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
11 EACH PIERS TO 11' (CIP LINTEL @ BEAM SEAT)
05/26/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. TOP OUT LINE 1/C.5-6 WHEN SP. INSP. CONFIRMS PAPER REMOVAL AND PA STRAP PLACEMENT.
2. 16' LINE 1/H-K AND LINE K/1-1.8
3. 4' LINE C/3-4
05/19/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
16' LINE 1 F-H; 12' LINE 1 H-K; 12' LINE K/1-2
12' LINE C/1-2
05/17/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
16' LINE 1/C-F; 8' LINE 3/H-K; 8' LINE /1-2
8' LINE 1/H-L
3000 PSI GROUT DOES NOT SUBSTITUTE FOR F'M OF 2000 PSI
8' LINE K/1-2
05/12/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12' LINE 1/C-H; 4' LINE C; 4' LINE L; TOP LINE 3 C-H;
4' LINE 1 H-K; 4' LINE 3 H-K
05/09/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. 31" LAP SPLICE REQUIRED LINE 1/C-H SO YOU MUST HOLD GROUT DOWN 8".
2. OK TO GROUT TO 8' LINE 3/C-4
3. 4' LINE 3 A-C
4. 4' LINE H
05/01/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
LINES 1/C-H, 3/C-H (0-4')
04/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ENTIRE PERIMETER OF BUILDING STEMWALLS, EXCEPT BEAM BEARING @ LINES C/2 & K/2
1. NEED #6 VERT. EACH FACE PER KEY NOTE #5 ON SHEET S2.1 @ BEAM BEARING. PLEASE PROVIDE STAMPED LETTER FROM ENGINEER FOR FIX.