Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T05CM00120
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/25/2007 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
10/20/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/12/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT OF TRASH ENCLOSURES (4) |
|
09/01/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2 NORTH TRASH ENCLOSURE -- 1ST LIFT OK TO GROUT |
|
08/29/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST LIFT TWO SOUTH ENCLOSURES |
|
08/23/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINTEL SPLICES @ TOP OF COLUMNS H.25 CLIPS AT FACIA FRONT & BACK |
|
07/27/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
07/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT OF NORTH PIER -- OK TO GROUT |
|
06/30/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH END PIER TOP OUT & NORTH END PIER 4TH LIFT OK TO GROUT. |
|
06/28/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO GROUT SOUTH COLUMNS 2-TOP OUT-1 4TH LIFT NORTH COLUMN - 3RD LIFT |
|
06/26/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 3 SOUTH COLUMNS 4TH LIFT-OK TO GROUT 2) 2 NORTH COLUMNS TOP OUT-OK TO GROUT |
|
06/23/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LIP CAPS OK |
|
06/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* FINAL LIFT ON WEST SIDE 13 COLUMNS @ COLUMN LINE 3 & SOUTH COLUMNS K @ 2.8 3RD LIFT ON NORTH COLUMN B @ 2.8 |
|
06/14/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MASONRY PROGRESS OK |
|
06/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* RECALL WHEN BALANCE OF EAST COLUMNS READY -- BEFORE YOU GROUT (8 TO HEIGHT). |
|
06/08/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MASONRY PROGRESS OK |
|
06/07/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT - SOUTH 1/2 E WALL |
|
06/02/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 11 EACH PIERS TO 11' (CIP LINTEL @ BEAM SEAT) |
|
05/26/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. TOP OUT LINE 1/C.5-6 WHEN SP. INSP. CONFIRMS PAPER REMOVAL AND PA STRAP PLACEMENT. 2. 16' LINE 1/H-K AND LINE K/1-1.8 3. 4' LINE C/3-4 |
|
05/19/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 16' LINE 1 F-H; 12' LINE 1 H-K; 12' LINE K/1-2 12' LINE C/1-2 |
|
05/17/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 16' LINE 1/C-F; 8' LINE 3/H-K; 8' LINE /1-2 8' LINE 1/H-L 3000 PSI GROUT DOES NOT SUBSTITUTE FOR F'M OF 2000 PSI 8' LINE K/1-2 |
|
05/12/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12' LINE 1/C-H; 4' LINE C; 4' LINE L; TOP LINE 3 C-H; 4' LINE 1 H-K; 4' LINE 3 H-K |
|
05/09/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. 31" LAP SPLICE REQUIRED LINE 1/C-H SO YOU MUST HOLD GROUT DOWN 8". 2. OK TO GROUT TO 8' LINE 3/C-4 3. 4' LINE 3 A-C 4. 4' LINE H |
|
05/01/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINES 1/C-H, 3/C-H (0-4') |
|
04/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ENTIRE PERIMETER OF BUILDING STEMWALLS, EXCEPT BEAM BEARING @ LINES C/2 & K/2 1. NEED #6 VERT. EACH FACE PER KEY NOTE #5 ON SHEET S2.1 @ BEAM BEARING. PLEASE PROVIDE STAMPED LETTER FROM ENGINEER FOR FIX. |