07/17/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1. CORRECTIONS MADE OK 2. OK TO BACKFILL 3. WATER TEST ONE RISER TO TEN FEET |
|
07/16/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* VERTICAL HROIZONTAL CHANGE OF DIRECTION TO BE A SWEEP CONTINUED TI NOT READY WILL RESULT IN A RE-INSPECTION FEE |
|
07/11/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. POST YOUR ADDRESS!! 2. VERTICAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 3. BRIDGING NOT PERMITTED - PIPE TO LAY ON A FIRM BASE 4. ALL BRANCH PIPING OVER FIVE FEET TO HAVE A FULL SIZE CLEANOUT |