Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM00115
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/23/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) # 3300 BREAK ROOM SINK. BELOW FLOOR OK. VENT OK. OK TO INSULATE HOT WATER. OK TO COVER | |
06/23/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
06/17/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PARTIAL APPROVAL - ROOMS 3302, 3308, 3310, 3312, 3301, 3303, 3305, 3307 IN WALL OK 500 NOT0 #4 FROM 6/9/05 |
|
06/16/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) TOILET RM # 1277-TRAP ARM MAY NOT CHANGE SIZE-LAVATORY MAX 1 1/2" TRAP ARM. 2) BREAKROOM # 1243 OK TO COVER. 3) TOILET ROOM # 1245 OK TO COVER. 4) ??? SINK IN # 1269 OK TO COVER. 5) TOILET RM # 1267 OK TO COVER. 6) SINKS IN # 1252 A & B INSTALLED PER REVISION. OK TO COVER. | |
06/14/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ROOM 3309 & 3311 IN WALL OK. ROOM 3330 DEMO OK. ROOM 3319 CAP OK. | |
06/09/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) IN WALL OK ROOMS 3315, 17, 21, 23, 25, 27, 3329, 31, 3314, 22, 24, 26 AND 28 2) ROOM 3319 REQUIRES CORRECT PERM CAP ON H20 1" LINE 3) ROOM 3330 REQUIRES CORRECT PERM CAPS OF CLOSET CARRIER 4) PLANS CALL FOR ALL CLOSET CARRIERS OT BE MADE TO ADA HEIGHT |