Permit: T05CM00067

Parcel: 141148170


Addresses:

9130 E VALENCIA RD


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM00067

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/25/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
1) CORRECTION MADE
2) RECEIVED (14) BACKFLOW CERTIFICATIONS
08/24/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) REVISED APPROVED PLAN ON SITE
08/23/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
08/22/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) MAKE FUNCTUAL ACC FLUSH VALVES
2) DRAIN FROM NORTHEAST FOUNTAIN DISPENSER TO BE RIGID FULL SIZE APPROVED PIPING OVER 5' REQUIRES P-TRAP OVER 15' REQUIRES P-TRAP AND VALVE FOR INDIRECT DRAINAGE
3) PROVIDE CLEANOUT PLUS AND COVER AT FOUNTAIN DISPENSOR
4) PROVIDE SEPERATE DRAINS FOR UPPER AND LOWER ICE MACHINE UNIT DRAINS
5) PROVIDE PROOF OF 1" AIR GAP OR BACKFLOW PROTECTION FOR SANITIZER FOR BULK CORE TANK
6) PROVIDE 1" AIR GAP FOR WALK IN COOLER CONDENSATE TO FLOOR SINK
7) CALL IN CORRECT WATER CONNECTION FOR RP FOR IRRIGATION. CALL IN ALL UNAPPROVED INSPECTION
8) NEED TO VERIFY SANITIZE BOWL OF 3 COMP SINK TO GO TO GREASE WASTE NOT INDIRECT WASTE
08/22/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CALL IN ALL UNAPPROVED INSPECTION CONCERNING PLUMBING
2) PROVIDE CONNECT ? FLOW PROTECTION FOR SANITIZER FOR BULK COILS TANK.
3) PLAN IS APPROVED IN ? 4-COMP SINK REQUIRES ONLY 3 COMPARTMENTS TO BE TRAPPED. SANITIZER BOWL SHOULD GO INDIRECT DRAINAGE TO SANITARY DRAIN NOT GREASE INTERCEPTOR.
4) PROVIDE CERTIFICATION FOR ALL BACKFLOW DEVICES ON SITE
08/17/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*