| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/18/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/17/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECOND FLOOR BOTTOM PLATES NOT BEARING ON STRUCTURE 2) WRONG PLAN ON SITE, REQUIRES 2889-2568 ON SITE |