Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/05/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS FROM 3/31/05 NOT COMPLIED WITH 2, 3, 5, 6, 8, 9, 10 AND 11 |
|
| 03/31/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RED HEADS LOOSE 2) REMOVE SCREEN AT DRYER VENT 3) FIRE STOP KITCHEN ARCH 4) NAIL PROTECT FHA STRAP DBL TOP PLATE AT WATER SERVICE 5) N.E. LIVING ROOM A-2 TRUSS NOT BEARING AT 3 PT 6) INTERIOR BEARING WALLS NOT PROPERLY ANCHORED EITHER 1/2 AB AT 4' ON CENTER OR HILT ? A7 8" ON CENTER 7) INTERIOR BEARING WALLS NOT CLIPPED TOP AND BOTTOM 14/SD3 8) REMOVE WIRE KINKS AND NAIL PROTECT 9) PROVIDE HOLDOWN AT NORTH EAST CORNER OF HOUSE 10) REMOVE COMBUSTIBLE MATERIAL AT FURNACE "B" VENT (ROOFING) 11) BLOCK ROOF OR INSTALL VENT AT HOLE |