Permit: T05CM00011

Parcel: 137294370

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/25/2005 FRAMING Approved IVRS - Inspection :*
04/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPLACE OVER NOTCHED KING STUDS AT SLIDER
2) HTT-16 MISSING BOLT AT MASTER
3) ELECTRIC WIRE HANGING AT MASTER TOILET
4) FIREBLOCK SOFFIT AT KITCHEN
04/19/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO TEST ON DWV'S
2) SHIM ALL HEADERS
3) HTT 16 IN MASTER NOT INSTALLED
04/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT B-VENTS
2) NO TEST ON DWV'S AND PROVIDE DETAIL FOR CHICAGO LOOP AT KITCHEN NOT ON PLANS