Permit: T05BU02985

Parcel: 136327690

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
01/10/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
01/05/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*ROMEX CONNECTOR INSTALLED BACKWARDS AT LIGHT FIXTURE
N.M CABLE SHEATH TO BE STRIPPED OFF CABLE & AT LEAST 6" OF CONDUCTOR TO BE LEFT INSIDE J-BOXES
GROUND FAN BOX
PLANS DON'T MATCH THE INSTALLATION ( CORRECT PLANS AT 201 N STONE)
SECURE N.M CABLES TO PANEL
CABLE @ SOUTH POST LIGHTS NEEDS TO ENTER THROUGH THE BACK OF THE BOX TO PROTECT CABLE FROM DAMAGE OF STAPLE MESH ETC
GROUND ALL METAL BOXES