Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05BU02918

Parcel: 10825284A


Addresses:

2410 E RIVER RD


Inspection Status: Approved

Inspection History: POOL/SPA ELECTRIC

Permit Number - T05BU02918

Inspection Description - POOL/SPA ELECTRIC

Inspection Status - Approved

Date Description Inspector Results Comments
06/20/2007 POOL/SPA ELECTRIC Approved IVRS - Inspection :*
06/11/2007 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
STILL NEED TO COMPLETE #1, 4, 9 FROM PREVIOUS INSP.
ALSO, FLEX TO BE PROPERLY STRAPPED GOING INTO HEATERS (WITHIN 12" OF TERMINATIONS)

NEED TO PAY REINSPECTION FEE BEFORE FINAL APPROVAL
06/01/2007 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
CHARLIE CLEMENS ON VACATION, DO NOT KNOW WHERE MOST OF THESE CONNECTIONS ARE, IF YOU DECIDE TO WAIT FOR HIM YOU CAN OR PLEASE HAVE CONTRACTOR WHO DID MAKE CORRECTIONS RESCHEDULE AND MEET ME TO GO OVER CORRECTIONS.
05/22/2007 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CONDUCTORS IN RACEWAYS TO BE DERATED FOR AMPACITY
NEC 310.15 B2
2. EMERGENCY SHUT OFF SWITCH FOR SPA MOTORS NOT WORKING -- NEC 680.41
3. SPA LIGHT NOT WORKING
4. TIGHTEN ALL BONDING CONNECTIONS
5. SHEETMETAL SCREWS NOT ALLOWED FOR GROUNDING & BONDING CONNECTIONS -- NEC 250.8
6. WIRE NUTS TO BE USED FOR NUMBER OF CONDUCTORS THEY ARE LISTED FOR -- NEC 110.3B
7. USE PROPER STRAPS FOR FLEX -- NOT TIE STRAPS TO EMT
NEC 356.30, 356.6
8. BREAKERS TO BE CORRECTLY IDENTIFIED AT PANEL DIRECTORY -- NEC 408.4
9. IDENTIFY ALL DISCONNECTING MEANS -- NEC 110.22
10. ONLY ONE CONDUCTOR UNDER LUGS (GROUND/BOND LUGS) NEC 110.3B
05/01/2007 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
OK HANDICAP ANCHORS
CALL FOR FINAL WHEN WATER IN AND ALL IS FULLY OPERATIONAL.
04/27/2007 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSPECTION FOR HANDICAP ANCHORS ONLY
1. STAINLESS STEEL ANCHORS ARE OK AND LUG CONNECTED TO ANCHORS OK. BUT WHERE BOND WIRE CONNECTS TO EXISTING BOND WIRE, USE A SPLIT BOLT (D.B) LIKE YOU DID ON THE HAND RAILS AND TIGHTEN ALL CONNECTIONS.

WILL NEED TO PAY REINSPECTION FEE.
IF NOT CORRECT NEXT INSPECTION.
04/16/2007 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
OK BONDING FOR ALL POOL & SPA HANDRAILS/LADDERS CUPS
NOTE: LUGS FOR BONDING OF HANDICAP RAMP CUPS FOR POOL AND SPA ARE NOT DIRECT BURIAL IDENTIFIED AND WILL NEED TO BE CORRECTED ALSO.
04/10/2007 POOL/SPA ELECTRIC Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
MEETING FOR BONDING COVERED WITHOUT INSPECTION
UNDER DECK. PIONEER POOLS, JASON
CHARLIE ALL PRESENT

BONDING LUGS PROVIDED BY POOL CONTRACTOR DOES NOT APPEAR TO BE OF THE DIRECT BURIAL TYPE (ARE NOT IDENTIFIED D.B) CONTRACTOR TO PROVIDE ADDITIONAL INFORMATION ON LUG. ALSO, HANDICAP JIG NOT INSPECTED, CONTRACTOR WILL PROVIDE THIS JIG AND PAPERWORK.

OK POOL, SPA LIGHTS -- BONDING & GROUNDING
OK TO FILL WATER
10/31/2006 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
PRE-GUNITE BONDING INSPECTION.

OK BONDING - OK TO GUNITE
OK TRENCH COVER

*NOTE: THERE ARE NO CUPS/JIGS BONDED
AT THIS TIME, ALSO NO DECK REBAR
I WILL NEED TO INSPECT THESE
BONDING CONNECTIONS BEFORE DECK IS POURED
RACEWAY TO LIGHTS IS NON-METALLIC
AND WILL NEED INSULATED #8CU GROUND.