Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA ELECTRIC
Permit Number - T05BU02918
Inspection Description - POOL/SPA ELECTRIC
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/20/2007 | POOL/SPA ELECTRIC | Approved | IVRS - Inspection :* | |
06/11/2007 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* STILL NEED TO COMPLETE #1, 4, 9 FROM PREVIOUS INSP. ALSO, FLEX TO BE PROPERLY STRAPPED GOING INTO HEATERS (WITHIN 12" OF TERMINATIONS) NEED TO PAY REINSPECTION FEE BEFORE FINAL APPROVAL |
|
06/01/2007 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* CHARLIE CLEMENS ON VACATION, DO NOT KNOW WHERE MOST OF THESE CONNECTIONS ARE, IF YOU DECIDE TO WAIT FOR HIM YOU CAN OR PLEASE HAVE CONTRACTOR WHO DID MAKE CORRECTIONS RESCHEDULE AND MEET ME TO GO OVER CORRECTIONS. |
|
05/22/2007 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CONDUCTORS IN RACEWAYS TO BE DERATED FOR AMPACITY NEC 310.15 B2 2. EMERGENCY SHUT OFF SWITCH FOR SPA MOTORS NOT WORKING -- NEC 680.41 3. SPA LIGHT NOT WORKING 4. TIGHTEN ALL BONDING CONNECTIONS 5. SHEETMETAL SCREWS NOT ALLOWED FOR GROUNDING & BONDING CONNECTIONS -- NEC 250.8 6. WIRE NUTS TO BE USED FOR NUMBER OF CONDUCTORS THEY ARE LISTED FOR -- NEC 110.3B 7. USE PROPER STRAPS FOR FLEX -- NOT TIE STRAPS TO EMT NEC 356.30, 356.6 8. BREAKERS TO BE CORRECTLY IDENTIFIED AT PANEL DIRECTORY -- NEC 408.4 9. IDENTIFY ALL DISCONNECTING MEANS -- NEC 110.22 10. ONLY ONE CONDUCTOR UNDER LUGS (GROUND/BOND LUGS) NEC 110.3B |
|
05/01/2007 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* OK HANDICAP ANCHORS CALL FOR FINAL WHEN WATER IN AND ALL IS FULLY OPERATIONAL. |
|
04/27/2007 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* INSPECTION FOR HANDICAP ANCHORS ONLY 1. STAINLESS STEEL ANCHORS ARE OK AND LUG CONNECTED TO ANCHORS OK. BUT WHERE BOND WIRE CONNECTS TO EXISTING BOND WIRE, USE A SPLIT BOLT (D.B) LIKE YOU DID ON THE HAND RAILS AND TIGHTEN ALL CONNECTIONS. WILL NEED TO PAY REINSPECTION FEE. IF NOT CORRECT NEXT INSPECTION. |
|
04/16/2007 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* OK BONDING FOR ALL POOL & SPA HANDRAILS/LADDERS CUPS NOTE: LUGS FOR BONDING OF HANDICAP RAMP CUPS FOR POOL AND SPA ARE NOT DIRECT BURIAL IDENTIFIED AND WILL NEED TO BE CORRECTED ALSO. |
|
04/10/2007 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* MEETING FOR BONDING COVERED WITHOUT INSPECTION UNDER DECK. PIONEER POOLS, JASON CHARLIE ALL PRESENT BONDING LUGS PROVIDED BY POOL CONTRACTOR DOES NOT APPEAR TO BE OF THE DIRECT BURIAL TYPE (ARE NOT IDENTIFIED D.B) CONTRACTOR TO PROVIDE ADDITIONAL INFORMATION ON LUG. ALSO, HANDICAP JIG NOT INSPECTED, CONTRACTOR WILL PROVIDE THIS JIG AND PAPERWORK. OK POOL, SPA LIGHTS -- BONDING & GROUNDING OK TO FILL WATER |
|
10/31/2006 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* PRE-GUNITE BONDING INSPECTION. OK BONDING - OK TO GUNITE OK TRENCH COVER *NOTE: THERE ARE NO CUPS/JIGS BONDED AT THIS TIME, ALSO NO DECK REBAR I WILL NEED TO INSPECT THESE BONDING CONNECTIONS BEFORE DECK IS POURED RACEWAY TO LIGHTS IS NON-METALLIC AND WILL NEED INSULATED #8CU GROUND. |