Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/25/2005 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 11/18/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*YOU MAY NOT USE ROOF TACKS TO NAIL SHEATHING. YOU NEED TO USE 8D SINKERS 6" ?? CENTER AT EDGES AND 12" O.C IN FIELD ROOF TACKS ARE NOT LONG ENOUGH-NOR DO THEY HAVE THE CORRECT BENDING STRENGTH 8 D VINYL COATED SINKERS MAY BE PURCHASED AT ANY HOME CENTER. THEY COST LESS DRIVE BETTER AND HOLD BETTER. |
|
| 11/10/2005 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* 1) YOU MUST REMOVE STUCCO/FOAM AND ATTACH LEDGER TO BLDG FRAME |