Inspection History Details
Permit: T05BU02579
Inspection Status: Approved
Inspection History: POOL/SPA ELECTRIC
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/21/2006 | POOL/SPA ELECTRIC | Approved | IVRS - Inspection :* | |
| 11/30/2005 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* 1) CONDUIT TO POOL FROM SWITCH AND FILTER AREA OK 2) GROUND WIRES OK |
|
| 11/25/2005 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection :* | |
| 11/22/2005 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXPOSE ALL CONDUIT (POOL LIGHTING RUN SO I CAN VERIFY DEPTH OF PVC). PVC TO BE MINIMUM 18" DEPTH EXCEPT COVERED BY CONCRETE 2) ALSO POOL PANEL DOESN'T HAVE THE REQUIRED WORKING CLEARANCE DUE TO POOL EQUIPMENT AND PIPING 3) POOL PANEL REQUIRED TO HAVE AN INSULATED GROUNDING CONDUCTOR PER NEC AND IRC |