Permit: T05BU02264

Parcel: 133033080


Addresses:

1475 N HOUGHTON RD


Inspection Status: Approved

Inspection History: STORMWATER INSTALL OF CONTROLS

Permit Number - T05BU02264

Inspection Description - STORMWATER INSTALL OF CONTROLS

Inspection Status - Approved

Date Description Inspector Results Comments
04/13/2006 STORMWATER INSTALL OF CONTROLS Approved STORMWATER CONTROLS HAVE BEEN INSTALLED AT THE GRADING LIMITS, AND THE DISTURBED AREA OUTSIDE THE GRADING LIMITS HAS BEEN HYDROSEEDED.
04/12/2006 STORMWATER INSTALL OF CONTROLS Correction Required CORRECTIONS ARE IN PROGRESS. THE AREA IS BEING PREPARED FOR HYDROSEEDING.
04/11/2006 STORMWATER INSTALL OF CONTROLS Correction Required CORRECTIONS PREVIOUSLY NOTED ARE IN PROGRESS. OWNER COOPERATION IS SUFFICIENT TO PREVENT ISSUANCE OF A STOP WORK ORDER
04/10/2006 STORMWATER INSTALL OF CONTROLS Correction Required I ISSUED ANOTHER CORRECTION NOTICE TO STEVE BRENNAN (AZ LIC. # 545257962 EXPIRATION 5-15-2023) WITH A 24 HOUR COMPLIANCE DEADLINE. THIS ADDITIONAL CORRECTION ORDER IS GRANTING ONE MORE DAY TO FACILITATED THE USE OF EQUIPMENT (I.E. SHEEPSFOOT AND SHREDDER/CHIPPER) TO PREPARE THE AREA FOR HYDROSEED AND STABILIZATION.
1. PREPARE ALL AREAS OUTSIDE GRADING LIMITS FOR HYDROSEED AND STABILIZATION.
2. COMPLETE INSTALLATION AND MAINTAINENCE OF SILT FENCE AND STRAW WATTLE AT THE SOUTH GRADING LIMIT.
ALSO REPAIR ALL STRING AND STAKE AT GRADING LIMITS.
3. PROVIDE STAKES IN STRAWBALES AT THE CULVERTS OR INSTALL ROCK RIP RAP AT THE INLETS AND OUTLETS.
4. REMOVE ALL DOWNED BRUSH OUTSIDE GRADING LIMITS AND RAKE OUT MOUNDED SOIL (SAME AS #1 ABOVE)
NON-COMPLIANCE WILL RESULT IN THE ISSUANCE OF A STOP WORK ORDER.
THE INSPECTOR WILL DETERMINE IF SUFFICIENT WORK HAS BEEN COMPLETED TO PREVENT ISSUANCE OF THE STOP WORK ORDER.
THE DEADLINE FOR RE-INSPECTION IS 2:00 PM 4-11-06.
03/30/2006 STORMWATER INSTALL OF CONTROLS Correction Required 1. STRAW WATTLE IS BEING INSTALLED ON SOUTH PERIMETER OF GRADING LIMITS.
2. SWPPP IS PARTIALLY UPDATED ADDITIONAL UPDATES WILL BE DRAWN IN AS THEY ARE COMPLETED.
3. HYDROSEED OF AREAS OUTSIDE THE GRADING LIMITS ARE SCHEDULED FOR APRIL 7, 2006.
4. CONSTRUCTION ENTRANCE IS RELOCATED DUE TO PREP FOR HOUGHTON ROAD TIE IN.

COMPLETE ALL ITEMS LISTED ON CORRECTION NOTICE. SUFFICIENT WORK IS IN PROGRESS TO HOLD OFF ON THE ISSUANCE OF A STOP WORK ORDER.
03/29/2006 STORMWATER INSTALL OF CONTROLS Correction Required I ISSUED A CORRECTION NOTICE TO STEVE BRENNAN (AZ LIC. # 545257962 EXPIRATION 5-15-2023) WITH A 24 HOUR COMPLIANCE DEADLINE. NON-COMPLIANCE WILL RESULT IN ISSUANCE OF A STOP WORK ORDER.
CORRECTIONS REQUIRED:
1. INSTALL SWPPP CONTROLS PER PLAN, MUST PROVIDE ADEQUATE CONTROL.
2. PROVIDE ALL UPDATES ON THE SWPPP.
3. STABILIZE (I.E. HYDROSEED) ALL DISTURBED AREAS OUTSIDE OF THE GRADING LIMITS.
4. RE-LOCATE THE CONSTRUCTION ENTRANCE AND UPDATE THE SWPPP.