10/25/2005 | POOL/SPA PLUMBING | Cancelled | IVRS - RI canceled | |
10/25/2005 | POOL/SPA PLUMBING | Approved | IVRS - Inspection :*VAC ALERT DEVICE INSTALLED PER MANUFACTURES INSTRUCTION | |
10/06/2005 | POOL/SPA PLUMBING | Not ready for Inspection | IVRS - Inspection :* 1) NEED LISTINGS FOR ANTI VORTEX COVERS FOR FILTER SUCTION PIPING AND SWIM JET SUCTION, AND POOL #2 SPA JET SUCTION 2) WILL NEED APPROVED ALTERNATE BACKUP SYSTEM WHICH SHALL PROVIDE VACUUM RELIEF SHOULD GRATE COVERS BE MISSING |
|
09/30/2005 | POOL/SPA PLUMBING | Not ready for Inspection | IVRS - Inspection :* PROVIDE CORRECT SUPPORT FOR ALL PVC SCH40 POOL PIPING AT 4' INTERVALS. PROVIDE INFORMATION ON POOL PUMPS & PADS BOING SECURED AND PLEASE PROVIDE THIS. PROVIDE CORRECT LID FOR SUMP PUMP, PROVIDE INFORMATION ON POSSIBLE VENT FROM THIS SUMP PUMP. POOL HEATER TO HAVE APPROVED TEMPERATURE & PRESSURE RELIEF DEVICES WITH GRAVITY DRAIN TO APPROVED RECEPTOR. PROVIDE INFORMATION ON POOL FILTER BACKWASH DRAINS IF EQUIPED AND SHOW POINT OF TERMINATION PROVIDE BACKFLOW PROTECTION FOR POOL FILL/ PROVIDE INFORMATION ON MAIN DRAIN ANTI ENTRAPMENT DEVICES. |