Permit: T05BU01913

Parcel: 12810079C


Addresses:

300 S CRAYCROFT RD


Inspection Status: Approved

Inspection History: GRADING - FINAL

Permit Number - T05BU01913

Inspection Description - GRADING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/28/2006 GRADING - FINAL Approved ALL PUNCHLIST ITEMS HAVE BEEN ADDRESSED
07/26/2006 GRADING - FINAL Not ready for Inspection PIPE STILL NOT REMOVED
07/13/2006 GRADING - FINAL Not ready for Inspection ADDITIONAL PAAL STRIPING TO BE DONE
DEBRIS TO BE REMOVED
PAINTING TO BE DONE
06/27/2006 GRADING - FINAL Not ready for Inspection RETREIVED FILE FROM LOREN DOWNTOWN
PER LOREN A REVISED DEV PLAN MUST BE SUBMITTED TO ZONING
LOREN IS ALSO REQUESTING A REVISED GRADING PLAN

BOTH OF THESE MUST BE RECVD BEFORE C OF O

PER SITE SUPER GARY C OF O SHOULD BE THURS
06/26/2006 GRADING - FINAL Not ready for Inspection MET WITH ARCHITECH, SUPERINTENDENT, LOREN MAKUS ON SITE
LOREN HAS ACCEPTED PUNCHLIST ITEMS:
#4 OK TO AS BUILT
#8 LOREN WILL ADDRESS WITH ZONING TO VERIFY ADA COMPLIANCE
#10 LOREN HAS OKAYED TO AS BUILT (DRAFTING ERROR) STRUCTURE NOT BUILT
#11 LOREN OKAYED NOT GETTING EXACT ELEVATIONS/GRADE ON BASIN/HARVESTING AREAS
06/22/2006 GRADING - FINAL Not ready for Inspection SPOKE TO TRE WITH RICK ENGINEERING TODAY
REITERATED THE PUNCH LIST ITEMS MUST BE BUILT TO PLAN OR REVIEWED AND APPROVED BY COT REVIEWER.
06/21/2006 GRADING - FINAL Not ready for Inspection TRIUMPH WORKING ON PUNCH LIST
RAMP FORMED UP
APPEARS SOME LANDSCAPE WORK HAS BEEN STARTED
06/16/2006 GRADING - FINAL Not ready for Inspection University of Phoenix
300 S. Craycroft Rd.
T05BU01919
Inspection date June 15, 2006

This is a PRELIMINARY punchlist ONLY.

1. Asphalt, curbing and striping not complete.
2. Keynote 11 - trash enclosure does not have gates yet.
3. Keynote 10 - all bike parking has not yet been installed.
4. Keynote 14 - sidewalk scuppers are not built to Standard Detail 204. Round pipe has been installed instead. Please address this and make appropriate revisions/as-builts as directed by City of Tucson Reviewer.
5. Keynote 18 - sidewalk scuppers are not built to Standard Detail 201. Round pipe has been installed instead. Please address this and make appropriate revisions/as-builts as directed by City of Tucson Reviewer.
6. Keynote 16 - rip rap pads not yet installed.
7. Keynote 17 - post barricades not installed in most locations.
8. Change to sidewalk at Southwest corner of project at corner of Williams Circle and Williams Boulevard. Plan shows a sidewalk and steps have been installed. Please address this and make appropriate revisions/as-builts as directed by City of Tucson Reviewer.
9. Sidewalk at Northwest driveway has not been tied into N/S sidewalk along Williams Circle.
10. Identify and address what appears to be three drainage grates/structures along Northwest parking area. Please address this and make appropriate revisions/as-builts as directed by City of Tucson Reviewer.
11. Grade all basin/water-harvesting areas to approved/stamped grading plan.
12. Install all curb cuts/drainage outlets per approved/stamped grading plan.
13. Install receiving curb ramp at Northwest corner of building sidewalk North of designated handicapped parking space.

Truncated domes are being painted a contrasting color from the concrete sidewalk a directed by Lee Ray Hanley.
06/15/2006 GRADING - FINAL Not ready for Inspection DID PRELIMINARY FINAL GRADING INSPECTION