Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - FINAL
Permit Number - T05BU01725
Inspection Description - GRADING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/16/2007 | GRADING - FINAL | Approved | FINAL GRADING APPROVED | |
| 04/19/2007 | GRADING - FINAL | Denied | 1) PROVIDE THE MOST RECENT REVISED GRADING PLAN FOR INSPECTION. 2) PROVIDE A CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD STATING THAT THE RET/DET BASINS AND THE DRAINAGE STRUCTURES ON SITE WERE BUILT IN ACCORDANCE WITH THE APPROVED PLAN. 3) COMPLETE 3' w X 6" d CONCRETE DRAINAGE CHANNEL LOCATED AT REAR OF BUILDING. 4) ENSURE ALL ROOF DRAINS A ROUTED UNDER ADJACENT SIDEWALKS. 5) COMPLETE WEIR-WALL WITH 5" OPENING AT SOUTH BASIN OUTLET. 6) INSTALL SAFETY RAILING WHERE APPLICABLE. 7) COMPLETE ROCK RIP RAP INSTALLATION AS SHOW ON YOUR APPROVED GRADING PLAN. 8) INSTALL TRASH ENCLOSURE GATES. 9) COMPLETE DRAINAGE SWALE AND RET/DET BASIN ALONG NORTH SIDE OF BLDG. 10) ENSURE RET/DET BASINS DRAIN TO BASIN OUTLET STRUCTURES. |