Inspection Status: Approved
Inspection History: POOL/SPA PRE-GUNITE
Permit Number - T05BU01667
Inspection Description - POOL/SPA PRE-GUNITE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2005 | POOL/SPA PRE-GUNITE | Approved | IVRS - Inspection :* | |
08/26/2005 | POOL/SPA PRE-GUNITE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MINIMUM 10 LB GAS TEST REQUIRED 2) COMPLETE PVC CONDUIT INTO MAIN ELECT PANEL AND EQUIP (CHECK AT FINAL) 3) WILL NEED VAC-ALERT AT FINAL 4) INSTALL HEATER PTR VALVE AND LINE 5) AUTO FILL LINE TO HAVE APPROVED TESTABLE BACKFLOW DEVICE 6) AT SUPPLY END 7) SUPPORT H20 LINES AWAY FROM REBAR TO MAINTAIN MIN CONCRETE ENCASEMENT OF REBAR 8) CHECK HEATER SPECS - MAY BE TO CLOSE TO WALL 9) STOPPED INSPECTION 10) PUT PLUMBING SUPPLY AND RETURN LINES ON PLAN |