| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/27/2005 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* 1) AVR VALVE 2) S/N 014416 |
|
| 09/26/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POOL ENCLOSURE GATES (5FT WOODEN) MUST BE SELF CLOSING AND LATCHING ( ON NORTH AND SOUTH SIDES OF HOUSE) |
|
| 09/21/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POOL ENCLOSURE GATES MUST BE SELF CLOSING AND SELF LATCHING 2) POOL BARRIER FENCE (METAL) WITHIN 5 FEET OF POOL EDGE MUST BE ELECTRICALLY BONDED 3) ATMOSPHERIC VACUUM RELIEF SYSTEM NOT INSTALLED 4) HAVE PLAN REVISED FOR ADDED GAS LINE AND POOL HEATER 5) EXPOSE POOL GAS LINE FOR BURIAL DEPTH AT EACH END 6) PROVIDE A GAS PRESSURE TEST 7) LIQUID TIGHT ELECTRICAL CONNECTORS LOOSE 8) REMOVED POOL LIGHT FOR INSPECTION OF GROUND POTTING |