Date Description Inspector Results Comments
01/25/2018 GRADING - FINAL Partial Approval MET ON SITE WITH SONNY DURANTE AND LOOKED OVER THE CURRENT CONDITIONS OF THE SITE AND WHAT NEEDS TO BE DONE PRIOR TO ALLOWING FOR THE FULL RELEASE OF A SITE. CURRENTLY THERE ARE A FEW ISSUES WITH THE SITE THAT CAUSE ME SOME CONCERNS THAT NEED TO BE ADDRESSED PRIOR TO THE FULL RELEASE. THE ORIGINAL DEVELOPER WILL BE TURNING OVER THE REMAINING LOTS TO ANOTHER DEVELOPER UNKNOWN IN THE FUTURE, THESE ARE THE FOLLOWING ITEMS THAT NEED TO BE ADDRESSED PRIOR TO THE FINAL: 1) COMPLETED ALL SIDEWALKS AS SHOWN ON THE APPROVED PLANS AND ENSURE THAT ALL ARE CODE COMPLIANT WITH ICC A117.1-2009. THE SIDEWALKS AND DRIVEWAYS IN FRONT OF LOTS #9 AND #10 ARE NON CONFORMING AT THIS TIME DUE TO THE CROSS SLOPES EXCEEDING 2% MAXIMUM. 2) THE SIDEWALKS COMING FROM COMMON AREA "C" WEST OF LOT #12, THE EASTERN SIDE EXCEEDS THE RUNNING AND CROSS SLOPES AND WILL NEED TO BE REMOVED AND REPOURED. ALSO SINCE THE RUNNING SLOPE IS MORE THAN 5% THIS AREA WILL ALSO NEED TO HAVE HANDRAIL PLACED ON BOTH SIDES OF THE SIDEWALK. THE WESTERN END EXCEEDS 5% RUNNING SLOPES AND WILL NEED TO HAVE HANDRAIL CONSTRUCTED ON BOTH SIDES OF THE SIDEWALK.
I HAVE REVIEWED THE GRADING PLANS, T05BU01518 TO VERIFY THAT THE RETAINING WALL ON THE NORTH SIDES OF LOTS #5 THRU #8 IS AS SHOWN ON THE APPROVED PLANS. THE EXISTING WALL IS TO REMAIN AS IS WITH A RETAINING WALL ON THE SOUTHSIDE TO PREVENT ANY LOAD FROM THE FILL MATERIAL TO CAUSE ANY DAMAGE.
07/25/2012 GRADING - FINAL Partial Approval FOUR LOTS LEFT TO BE BUILT.
RET/DET BASIN NEEDS MAINT.
PROVIDE A CERT STATEMENT FROM THE ENG OF RECORD, PROVIDE AN AS-BUILT DRAWING
07/31/2008 GRADING - FINAL Partial Approval REVIEWED PROPOSED STABILIZATION METHOD FOR FINAL GRADING APPROVAL OF SITE.
NEED SPECS ON SOIL AMENDMENT BEING USED/APPLY PER SPECS.
PROVIDE A SILT TRAP ( 2-4" DEEP 1/2" MINUS ROCK) AT EACH CURB OPENING FOR DRIVEWAYS.
03/12/2008 GRADING - FINAL Partial Approval SITE STILL UNDER CONSTRUCTION. FOUR HOMES COMPLETED , SITE WORK DONE. SOME LOTS STILL TO BE CONSTRUCTED AND ARE NOT STABILIZED.