Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/16/2006 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
| 08/18/2005 | POOL/SPA FINAL/BARRIER | Partial Approval | IVRS - Inspection :* 1) BEFORE I SIGN OFF ON THIS POOL PLEASE FAX COPY OF PIPING AND OR DRAIN SUCTION, BLOWING SYSTEMS 2) NEED PLAN THAT WAS APPROVED TO OBTAIN PERMIT |
|
| 08/11/2005 | POOL/SPA FINAL/BARRIER | Partial Approval | IVRS - Inspection :* 1) SVRS NOT REQUIRED (SKIMMER ONLY) (PLUMBING WAS APPROVED 7/8/05) 2) 48" POOL BARRIER OK PER CODE 3) OK TO PLASTER AND FILL BOTTOM BOND BARRIER TO GROUND |
|
| 08/09/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE CITY OF TUCSON DOCUMENTED PROOF THAT POOL INSTALLATION COMPLIES WITH AG 106.3 AND ASME A 112.19.17. THERE IS NO DESIGN CRITERIA ON SITE INDICATING COMPLIANCE 2) POOL BARRIER MUST BE 5 FEET HIGH WITH SELF CLOSING/ LATCHING GATES WITH LATCH 54" ABOVE GROUND |