Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
Permit Number - T05BU01355
Inspection Description - POOL/SPA FINAL/BARRIER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/02/2005 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
09/01/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POOL COVERS TO BE STAMPED A.S.M.E. APPROVED 2) GALS PER MIN OF SYS TO BE ON PLANS SIZE COVERS ACCORDINGLY 3) BOND POOL LIGHT J-BOX 4) WET NICHE FIXTURE BOND CONNECTION NOT COMPLETELY ENCASED IN COMPOUND 5) LIGHT CLIP WON'T CATCH WHEN SCREW IS TIGHT ON 6) USE A NON REMOVABLE SCREW AT WINDOW |