Inspection Status: Approved

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
11/03/2005 POOL/SPA PRE-GUNITE Approved IVRS - Inspection :*
11/01/2005 POOL/SPA PRE-GUNITE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLAMP FOR BOND WIRE AT LITE NOT APPROVED FOR BURIAL IN CONCRETE
2) MUST BE BRASS WITH BRASS SCREWS
08/31/2005 POOL/SPA PRE-GUNITE Partial Approval IVRS - Inspection :*
1) REBAR OKAY
2) NO BOND WIRES FOR LIGHT OR EQUIPMENT INSTALLED
3) AT FINAL, PROPER BACK FLOW PREVENTION WILL BE REQUIRED AT SUPPLY LINE
4) INSTALL VACUUM BREAKER ON HOSE BIB
5) AN SVRS WILL BE REQUIRED AT FINAL
6) IF A 4' BARRIER FENCE IS USED, THEN THE WALL GATES AROUND THE YARD PERIMETER WILL NEED TO BE MINIMUM 5' HI FROM THE OUTSIDE
07/11/2005 POOL/SPA PRE-GUNITE Not ready for Inspection IVRS - Inspection :*
1) NO PLUMBING, NO REBAR
2) NO PLAN FOR REBAR INCLUDED IN PLAN TUBE