Permit: T05BU01083

Parcel: 141283500

Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Date Description Inspector Results Comments
07/19/2005 POOL/SPA PLUMBING Approved IVRS - Inspection :*
07/15/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*
1) LATCHES TO BE 54" ABOVE F/FLR
2) REPLACE ANTI-SIPHON AT HOSE BIB
3) BOND METAL BARRIER
4) CU FEMALE FITTING INSIDE WALL, REQS A BRASS FITTING BETWEEN CU. AND GALV.
5) LEAVE POOL COVERS ON SITE WITH FLOW RATE OF SYSTEM
06/16/2005 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*
1) POOL SUCTION INLETS ARE PRESENTLY 36" APART EDGE TO EDGE. YOU WILL BE REQUIRED TO HAVE 36" BETWEEN EDGES OF ANTI-VORTEX COVER INLETS FOR FINAL INSPECTION
2) CONDUIT AND BOND WIRES INSTALLED BETWEEN EQUIPMENT AND POOL OK. WIRING AND HOME RUN CONDUIT NOT INSTALLED
3) YOU MUST COMPLY WITH AG-106 BY FINAL INSPECTION