Inspection History Details
Inspection Status: Continued
Inspection History: GRADING - INTERMEDIATE
Permit Number - T05BU01005
Inspection Description - GRADING - INTERMEDIATE
Inspection Status - Continued
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2012 | GRADING - INTERMEDIATE | Continued | NO ACTIVITY, NO CHANGES. SITE NOT COMPLETE | |
| 10/29/2008 | GRADING - INTERMEDIATE | Correction Required | SPOKE WITH SUPERINTENDENT AND PROJECT MANAGER ABOUT TRANFERRING NOI AND PERMITS FOR PROJECT. ADEQ REQUIRES A NEW NOI SUBMITTAL AND THE COT HAS TRANSFERRED |
|
| 02/23/2007 | GRADING - INTERMEDIATE | Correction Required | PER FINAL GRADING INSPECTION COMPLETED 2/22/07, SEVERAL DEFICIENCIES WERE FOUND WITH ASPHALT GRADES CAUSING SIGNIFICANT PONDING. PRIOR TO FINAL GRADING APPROVAL FOR PERMIT #T05BU1005 BY THE CITY OF TUCSON ENGINEERING SECTION, THE FOLLOWING AREAS MUST BE CORRECTED: 1) PONDING OF WATER ON CURB-LINE AT EAST SIDE OF BLDG#1 IN PARKING LOT. 2) NE CORNER OF BLDG#1, HOLE OR DEPRESSION IN ASPHALT CAUSING PONDING. 3) WEST SIDE OF BLDG #2 NEAR LANDSCAPE ISLAND, WATER DOES NOT DRAIN TO SWALE. 4) SW CORNER, SOUTH OF BLDG #2, SIGNIFICANT PONDING OF WATER. 5) SOUTH SIDE OF BLDG#3 - MUST HAVE A DEFINED SWALE - WATER DOES NOT DRAIN TO EXISTING CATCH BASIN. PER APPROVED GRADING PLAN, SURFACE WATER MUST DRAIN TO INSTALLED CATCH BASIN. |